Label specification terms, defined
Eight terms decide whether a datasheet means what you think it means. Each is defined in one sentence, with the unit it is quoted in, the method behind the number, and the misreading that causes the most wrong decisions.
Last updated: 2026-11-04
At a glance
| Term | Unit | Test method |
| Initial tack | newton (N); a ball number is also used as shorthand on some datasheets | GB/T 4852 (rolling ball) or FINAT FTM 9 (loop tack) — different methods, so the numbers are not comparable |
| 90° peel | N/25 mm (occasionally N/inch) | GB/T 2792 or FINAT FTM 2: 300 mm/min at 90°, 23 ± 2 °C / 50 ± 5 % RH, after 20 min or 24 h dwell |
| Shear (holding power) | hours to failure under a standard load and area | GB/T 4851 or FINAT FTM 8: a defined area loaded in shear at 23 ± 2 °C, time to slip recorded |
| Release force | mN/25 mm or g/25 mm | FINAT FTM 3 (low speed, 0.3 m/min) and FTM 4 (high speed, 10 m/min), peeled at 180° |
| Minimum application temperature | °C | No ISO method: apply at the stated temperature, dwell 24 h at 23 °C, then peel — industry practice, so treat limits as approximate |
| Service temperature | °C | After 24 h dwell at 23 °C, expose to the stated temperature (e.g. 70 °C for 24 h), then re-test peel or shear |
| Grammage | g/m² | ISO 536 (paper and board) / GB/T 451.2 |
| Caliper | μm | ISO 534 / GB/T 451.3, measured under a defined pressure |
Initial tack初粘力
The force needed to separate a label from a standard surface immediately after brief, light contact, before the adhesive has fully wet out.
- Unit
- newton (N); a ball number is also used as shorthand on some datasheets
- Test method
- GB/T 4852 (rolling ball) or FINAT FTM 9 (loop tack) — different methods, so the numbers are not comparable
- Common misreading
- That high tack means strong adhesion. Tack describes first contact only; a soft, high-tack adhesive often fails earlier in shear.
See where this shows up in the catalogue →
90° peel90° 剥离力
The force per unit width needed to pull a label off a standard plate at 90°, at fixed speed, after a set dwell.
- Unit
- N/25 mm (occasionally N/inch)
- Test method
- GB/T 2792 or FINAT FTM 2: 300 mm/min at 90°, 23 ± 2 °C / 50 ± 5 % RH, after 20 min or 24 h dwell
- Common misreading
- That the highest value wins. High peel makes clean removal harder, can tear the face, and is wasted where the label is never taken off.
See where this shows up in the catalogue →
Shear (holding power)剪切强度(持粘)
The resistance of a bonded label to a steady load pulling along the surface — measured as the time the bond survives before sliding.
- Unit
- hours to failure under a standard load and area
- Test method
- GB/T 4851 or FINAT FTM 8: a defined area loaded in shear at 23 ± 2 °C, time to slip recorded
- Common misreading
- That tack, peel and shear rise together. They trade off — a soft, high-tack adhesive flows and fails in shear sooner.
See where this shows up in the catalogue →
Release force离型力
The force needed to pull a liner away from the adhesive at a stated speed and angle, deciding whether a web runs cleanly.
- Unit
- mN/25 mm or g/25 mm
- Test method
- FINAT FTM 3 (low speed, 0.3 m/min) and FTM 4 (high speed, 10 m/min), peeled at 180°
- Common misreading
- That lower release is always better. Too low and the liner lifts, wrinkles, or the web breaks at high line speed.
See where this shows up in the catalogue →
Minimum application temperature最低贴标温度
The lowest surface temperature at which the adhesive still wets out enough to bond; below it, tack collapses and edges lift.
- Unit
- °C
- Test method
- No ISO method: apply at the stated temperature, dwell 24 h at 23 °C, then peel — industry practice, so treat limits as approximate
- Common misreading
- Confusing it with service temperature. A label applied below its minimum never bonds, however well it survives heat afterwards.
See where this shows up in the catalogue →
Service temperature服役温度(使用温度)
The temperature range a correctly applied label tolerates in use without lifting, shrinking or oozing, measured after full wet-out.
- Unit
- °C
- Test method
- After 24 h dwell at 23 °C, expose to the stated temperature (e.g. 70 °C for 24 h), then re-test peel or shear
- Common misreading
- Assuming a label can be applied at its service temperature. Bonding and surviving are two separate limits.
See where this shows up in the catalogue →
Grammage克重
Mass per unit area of a face stock, adhesive or liner, expressed in grams per square metre and measured on the dry sheet.
- Unit
- g/m²
- Test method
- ISO 536 (paper and board) / GB/T 451.2
- Common misreading
- That more grammage means more thickness. Density differs — 80 g/m² coated and 80 g/m² woodfree have different calipers.
See where this shows up in the catalogue →
Caliper厚度(caliper)
Thickness of a single sheet measured under a specified pressure, expressed in micrometres; the input to stiffness, die-cutting and roll diameter.
- Unit
- μm
- Test method
- ISO 534 / GB/T 451.3, measured under a defined pressure
- Common misreading
- That caliper alone sets stiffness. Stiffness rises roughly with the cube of caliper, and also with the material's modulus.
See where this shows up in the catalogue →
Values quoted on this site follow these methods and are verified at 23 ± 2 °C / 50 ± 5 % RH unless stated otherwise. Where a datasheet quotes a number without its method, the number is not comparable with anything.
Ask how we test a specific construction